Open the battery chamber.
|
● |
|
|
|
● |
Install 3 pcs AA type of batteries and close
the chamber. |
|
Activating the red power switch, the green LED light indicating power on.
(When LED is red, batteries power will be exhausted)
|
● |
|
|
|
● |
Activate the first black switch for
horizontal line projection. |
|
Warning:
| Do use the instrument as intended
only.
| Use of controls or adjustment of
performance of procedures other than those specified here may result in
hazardous radiation exposure
| Meeting International Standard
IEC-825,EMC tested and laser classified according to CE marking.
| Don't use it, if the circustance
temperature is over 45oC (113oF). |
| | |
Caution:
● |
The instrument
is precise, must prevent throwing, crashing and shock, when use, move and
store. |
● |
Keep the
instrument to be dry and clean, when use or un-use. |
● |
When you don't
use it, please turn off power and keep in our special box for protection
the instrument. |
|
|
● |
Activate the second black switch for vertical line
projection. |
|
Activate the third black switch for right angle projection between two
vertical planes.
|
● |
|
|
|
● |
360° free rotation after unlocking the rear knob. |
|
Caution: For auto-calibration the air bubble has to be inside the ring.
The air bubble must be on the center, If not on the center that means the
instrument should be adjusted. Adjustment method as follows:
|
● |
|
|
|
How to adjust if air bubble on A.B.C.D.
position. |
A. |
Turn the front adjustment screw clockwise till air bubble
is on the center. |
B. |
As A. just turn the adjustment screw counter-clockwise. |
C. |
Turn the side adjustment screw clockwise till bubble is on
the center. |
D. |
As C. just turn the adjustment screw counter-clockwise. |
|
Turn off the main power switch when not in use.
|
● |
|
|
|
|
Please keep in our special box for protecting the instrument.
|
● |
|
|
Warning:
| Do use the instrument as intended
only.
| Use of controls or adjustment of
performance of procedures other than those specified here may result in
hazardous radiation exposure.
| Meeting International Standard
IEC-825,EMC tested and laser classified according to CE marking.
| Don't use it, if the circustance
temperature is over 45oC (113oF). |
| | |
Caution:
● |
The instrument
is precise, must prevent throwing, crashing and shock, when use, move and
store. |
● |
Keep the
instrument to be dry and clean, when use or un-use. |
● |
When you don't
use it, please turn off power and keep in our special box for protection
the instrument. |
|